NSS4U24SA-SS   NSS4U24SA-SS
The NSS4U24SA-SS RAID subsystem is powered by dual-active or a single RAID controller. Each RAID controller comes with four (4) SAS multi-lane host ports that are defined as IN ports and OUT ports. The OUT ports can be used to connect the IN ports of other NSS4U24SA-SS systems in order to expand capacity and to multiply RAID computing power. By cascading NSS4U24SA-SS enclosures on the host links, the throughput from multiple systems can be joined and the 12Gbps bandwidth per port can be leveraged.
 
ï

 

 

The EonStor NSS4U24SAR-SS RAID subsystem is powered by dual-active or a single RAID controller. Each RAID controller comes with four (4) SAS multi-lane host ports that are defined as IN ports and OUT ports. The OUT ports can be used to connect the IN ports of other A24S systems in order to expand capacity and to multiply RAID computing power. By cascading NSS4U24SAR-SS enclosures on the host links, the throughput from multiple systems can be joined and the 12Gbps bandwidth per port can be leveraged.

The NSS4U24SAR-SS RAID enclosure is designed with all the sophisticated high availability features including redundant RAID controllers, a common backplane, dedicated cross-controller ‘sync. cache’ channels, redundant cooling and power supply modules. Highest performance and spindle density is achieved within the compact design which provides dozens of terabytes in a 4U chassis.

The NSS4U24SAR-SS takes advantages of SAS interface technology in terms of its ease of cabling and many folds of bandwidth compared with its SCSI predecessors. The system accommodates high capacity and low-cost SATA-II 3Gbps disk drives. With the additional cascade ports, RAID or expansion enclosures can be easily attached to include a total of an astonishing 264TB capacity (using 1TB SATA drives). As a capacity champion, the NSS4U24SAR-SS does not compromise on its data protection functionality. The NSS4U24SAR-SS supports RAID levels 0, 1, 3, 5, 6, multi-level logical volumes, and all the renowned firmware functionality as other EonStor series models.

 

 

 

If using 1TB SATA drives in this configuration, a maximum of 264TB capacity can be included for a direct-attached configuration. SAS cables are strung along the cascade ports of the 3 RAID enclosures, and expansion enclosures are attached to each RAID system. 

 

Scalability for each RAID enclosure:       

  • Redundant-controller RAID – 2 JBOD (EonStor S16S-J1000-R)
  • Single-controller RAID – 4 JBOD (EonStor S16S-J1000-S)

RAID levels:

RAID level 0, 1(0+1), 3, 5, 6, 10, 30, 50, 60; arrays of different RAID levels can co-exist in a configuration.

Host connectivity: 

  • NSS4U24SAR-SS - 8 SFF-8088 multi-lane SAS
  • NSS4U24SA-SS - 4 SFF-8088 multi-lane SAS

Drive connectivity: 

  • 24 SATA HDD via a common backplane
  • Drive-side expansion via a SAS multi-lane SFF-8088 per controller

NOTE: expansion to the S16S JBOD requires SFF-8088-to-SFF-8470 cables

Enclosure dimensions: 4U rackmount enclosure

Dimensions Without Chassis Ears With Chassis Ears
Height 174.4mm(6.86 inches) 174.4mm(6.86 inches)
Width 445mm(17.5 inches) 482mm(19 inches)
Length 498mm (19.6 inches) 514mm (20.2 inches)

Package dimensions:

520(H) x 580(W) x 780(D)mm (20.5 x 22.8 x 30.7 inches)

System weight:

Gross weight – 41kg; Net weight – 38kg (without disk drives

Electrical:

Input Voltage

100VAC @ 8A

240VAC @ 4A with PFC (auto-switching)

Capacity per PSU: 405W

Frequency 50 to 60Hz
Power Consumption 434W: R2130; 408.9W: G2130 (max.)

Environmental:

Humidity

Operating: 5% to 90% (non-condensing)

Non-operating: 5% to 95% (non-condensing)

Temperature

Operating: 0º to 40ºC (32º F to 104º F)

0º to 35ºC (32º F to 95º F, if BBU is applied)

Non-operating: -40º to 60ºC (-40º F to 149º F)

Altitude

Operating:  3,658m (12,000 ft.)

Non-operating: 12,192m (40,000 ft.)

Shock (Half-sine)

Operating: 5G, half-sine, 11ms pulse width

Non-operating: 15G, half-sine, 11ms pulse width

Package: 60G, half-sine, 11ms pulse width

Vibration

(Random)

Operating: 5 to 500Hz, 0.25Grms, X/Y/Z Sine

Non-operating: 5 to 500Hz, 1.88Grms, X/Y/Z Sine

(Sine)

Operating: 5 to 500Hz, 0.2Grms, X/Y/Z Sine, 30min/sweep

Non-operating: 5 to 500Hz, 1.0Grms, X/Y/Z Sine, 30min/sweep

Acoustic Noise 65dBA boundary, 60dBA normal

Regulatory:

  • IEC 60068-2,
  • MIL-STD-810E/883E,
  • ISTA,
  • ASTM-D3332,
  • IPC-TM-650
  • IEC 1000-4
  • IEC 1000-3-2, IEC 1000-3-3
  • ISO 7779/3744
  • RoHS
  • Microsoft WHQL-Windows Server 200

EMC

  • CE
    • EN 55022: 1998/A1: 2000/A2: 2003
    • EN 61000-3-2: 2000/A2: 2005
    • EN 61000-3-3: 1995/A1: 2001
    • EN 55024: 1998/A1: 2001/A2: 2003
  • FCC (FCC Part 15, subpart B)
  • BSMI (CNS 13438)

Safety

  • UL (60950-1: 2003)
  • BSMI
    • CNS 14336: 1993
    • IEC 60950-1, First Edition

 



 

There are no accessories for this product at this time.





Solutions Rackmount Servers Storage Workstation
Rackmount Servers
Storage Servers
Blade Servers
HPC Cluster
Gpu Computing
1U Rackmount server
2U Rackmount server
3U Rackmount server
4U Rackmount server
5U Rackmount server
6U Rackmount server
7U Rackmount server
8U Rackmount server
9U Rackmount server
NAS
SAN
DAS
iSCSI
BackUp
Promise Technologies
Intel Workstations
AMD Workstations
GPU Supercomputing Workstations
High Performance Workstations
AMD FireStream
NVIDIA Tesla