The NSS4U24SA-FC SAN-ready subsystem combines the cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth.
The NSS4U24SA-FC SAN-ready subsystem combines the cost-effective
SATA drives in a high availability 4G FC array. IT managers will
find it is an easy-to-use and easy to maintain storage solution for
their DAS, Fibre Channel SAN and clustered servers or any
application requiring dedicated bandwidth.
Ultra-high-density, 4U-profile, 24-bay enclosure
Single or dual-active redundant RAID controllers
Two (2) 4G-FC host channels per RAID controller
Expansion via SFF-8470 SAS wide links
Designed for SATA-II (3Gbps) disk drives
Intelligent load-balancing internally & externally by the
EonPathâ„¢ multipathing software
SANWatch® storage management software
RAID
Multiple arrays with Dedicated,
Global, or Enclosure-specific hot
spares
Firmware-embedded utility via
LCD keypad or RS-232C port
VT-100 terminal emulation via
RS-232C
Telnet access via the onboard
Ethernet port
10/100 BaseT Ethernet for
out-of-band management
Two (2) COM ports for local
access to firmware-embedded utility
and UPS connectivity
Java-based SANWatch software
with Snapshot protection:
Graphical user interface
Local/remote management;
in-band or out-of-band via
TCP/IP
Centralized management to
monitor and administer multiple
RAID units on one screen
Secure link over SSL
Configuration Client for easy
access to the configuration utility
screen
SNMP 2.0 MIBs with get and set
commands
SAN Management
Up to 1024 LUNs (if sufficiently
large memory is used with the proper
settings)
Indicators
Onboard alarm
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Seven (7) per RAID
controller module
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply
unit
One (1) per BBU module
Two (2) per FC port
Module failure alert through I2C
bus
Event notifications sent over
email, fax, LAN broadcast, SNMP
traps, MSN messenger, SMS short
messages
System alerts through Java-based
RAIDWatch manager
IOSmart
IOSmart allows for the flexible
configuration of logical drives, logical
volumes and logical partitions and
ensures instant RAID availability via
background logical drive initialization.
Fibre loops' load balancing is provided
within the subsystem. The firmware' s
Adaptive Write Policy and Guaranteed
Latency I/O algorithms improve write
performance and ensure fast and
continuous data flow.
DrvSmart
The DrvSmart utilities manage disk
drive defects and help ensure data
integrity. One of the main DrvSmart
functions, Media Scan, retrieves data
from degraded or damaged hard drives and
handles low quality drives in both the
degraded mode and during the rebuild
process. Other DrvSmart features include
disk cloning, drive roaming, SMART,
transparent resetting of non-responsive
hard drives, RAID parity update tracking
and recovery.
SysSmart
SysSmart combines enclosure
monitoring and firmware management
capabilities in order to minimize the
chance of down time caused by hardware
failures. The SysSmart functions include
the event-triggered cache flush and the
various monitoring approaches combined
with the powerful RAIDWatch manager.
Component status, voltage and
temperature readings, and system events
are instantly revealed through the
manager's graphical interface.
Physical/Electrical
Interfaces
Eight (8) or four (4) FC ports
that receive SFP fiber optic
transceivers
Two (2) COM ports on each
controller module for RS-232C serial
port (38400, n, 8, 1) and UPS
support
One (1) 10/100BaseT Ethernet
port on each controller module
Power Supply Module
Three (3) redundant, hot-swappable power
supplies with PFC
Input
100V at 16A, 240V at 8A with PFC
(auto-switching)
50 to 60Hz
Output
(Maximum output: 405 Watts)
+12.0V
24A max.
+ 5.0V
36A max.
+ 3.3V
30A max.
Hold-up Time
At least 20ms at 115/230VAC full
load after a loss of AC input
Cooling Module
Two (2) redundant, dual-fan cooling
modules Maximum Air Flow: High speed:
48.12 CFM
Environmental
Specifications
Temperature
Operating: 0º
to 40ºC
0º to 35ºC
(with BBU)
Non-operating: - 40º to 60ºC
Relative
Humidity
5% to 95%
(non condensing - operating and
non-operating)
Altitude
Operating:
sea level to 12,000 ft
Non-operating: sea level to
40,000 ft
Dimensions
Chassis without handles: 445(W)
x 174.4(H) x 498(D) mm (17.5 x 6.86
x 19.6 inches)
Chassis with handles: 482(W) x
174.4 (H) x 514(D) mm (19 x 6.86 x
20.2 inches)
Package: 520(H) x 580(W) x
780(D) mm (20.5 x 22.8 x 30.7
inches)
System weight
Net weight: 38kg
Gross weight: 41kg (without disk
drives)
There are no accessories for this product at
this time.