The NSS4U24SAR-FC SAN-ready subsystem combines the cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth.Redundant Controller Installed.
The NSS4U24SAR-FC SAN-ready subsystem combines the cost-effective
SATA drives in a high availability 4G FC array. IT managers will
find it is an easy-to-use and easy to maintain storage solution for
their DAS, Fibre Channel SAN and clustered servers or any
application requiring dedicated bandwidth.
Ultra-high-density, 4U-profile, 24-bay enclosure
Single or dual-active redundant RAID controllers
Two (2) 4G-FC host channels per RAID controller
Expansion via SFF-8470 SAS wide links
Designed for SATA-II (3Gbps) disk drives
Intelligent load-balancing internally & externally by the
EonPathâ„¢ multipathing software
SANWatch® storage management software
RAID
Multiple arrays with Dedicated,
Global, or Enclosure-specific hot spares
Firmware-embedded utility via LCD
keypad or RS-232C port
VT-100 terminal emulation via
RS-232C
Telnet access via the onboard
Ethernet port
10/100 BaseT Ethernet for
out-of-band management
Two (2) COM ports for local access
to firmware-embedded utility and UPS
connectivity
Java-based SANWatch software with
Snapshot protection:
Graphical user interface
Local/remote management; in-band
or out-of-band via TCP/IP
Centralized management to
monitor and administer multiple RAID
units on one screen
Secure link over SSL
Configuration Client for easy access
to the configuration utility screen
SNMP 2.0 MIBs with get and set
commands
SAN Management
Up to 1024 LUNs (if sufficiently large
memory is used with the proper settings)
Indicators
Onboard alarm
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Seven (7) per RAID controller
module
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Two (2) per FC port
Module failure alert through I2C bus
Event notifications sent over email,
fax, LAN broadcast, SNMP traps, MSN
messenger, SMS short messages
System alerts through Java-based
RAIDWatch manager
IOSmart
IOSmart allows for the flexible
configuration of logical drives, logical
volumes and logical partitions and ensures
instant RAID availability via background
logical drive initialization. Fibre loops'
load balancing is provided within the
subsystem. The firmware' s Adaptive Write
Policy and Guaranteed Latency I/O algorithms
improve write performance and ensure fast
and continuous data flow.
DrvSmart
The DrvSmart utilities manage disk drive
defects and help ensure data integrity. One
of the main DrvSmart functions, Media Scan,
retrieves data from degraded or damaged hard
drives and handles low quality drives in
both the degraded mode and during the
rebuild process. Other DrvSmart features
include disk cloning, drive roaming, SMART,
transparent resetting of non-responsive hard
drives, RAID parity update tracking and
recovery.
SysSmart
SysSmart combines enclosure monitoring
and firmware management capabilities in
order to minimize the chance of down time
caused by hardware failures. The SysSmart
functions include the event-triggered cache
flush and the various monitoring approaches
combined with the powerful RAIDWatch
manager. Component status, voltage and
temperature readings, and system events are
instantly revealed through the manager's
graphical interface.
Physical/Electrical
Interfaces
Eight (8) or four (4) FC ports that
receive SFP fiber optic transceivers
Two (2) COM ports on each controller
module for RS-232C serial port (38400,
n, 8, 1) and UPS support
One (1) 10/100BaseT Ethernet port on
each controller module
Power Supply Module
Three (3) redundant, hot-swappable power
supplies with PFC
Input
100V
at 16A, 240V at 8A with PFC
(auto-switching)
50
to 60Hz
Output
(Maximum output: 405 Watts)
+12.0V
24A max.
+ 5.0V
36A max.
+ 3.3V
30A max.
Hold-up Time
At
least 20ms at 115/230VAC full load
after a loss of AC input
Cooling Module
Two (2) redundant, dual-fan cooling modules
Maximum Air Flow: High speed: 48.12 CFM
Environmental
Specifications
Temperature
Operating: 0º to
40ºC
0º to 35ºC
(with BBU)
Non-operating: - 40º to 60ºC
Relative
Humidity
5% to 95% (non
condensing - operating and
non-operating)
Altitude
Operating: sea
level to 12,000 ft
Non-operating: sea level to 40,000
ft
Dimensions
Chassis without handles: 445(W) x
174.4(H) x 498(D) mm (17.5 x 6.86 x 19.6
inches)
Chassis with handles: 482(W) x 174.4
(H) x 514(D) mm (19 x 6.86 x 20.2
inches)
Package: 520(H) x 580(W) x 780(D) mm
(20.5 x 22.8 x 30.7 inches)
System weight
Net weight: 38kg
Gross weight: 41kg (without disk
drives)
There are no accessories for this
product at this time.