The NSS3U16SA-FC SAN-ready subsystem combines the cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth.
The NSS2U12SA-SI & NSS2U8SA-SI feature
reliable SCSI host interfaces and large, cost-effective SATA disk
drives. The series models are ideal for building a shared storage
pool for data backup in the digital media, broadcast, medical
imaging, and security/ surveillance environments.
SCSI-320 to SATA-II (3Gbps) single controller RAID subsystem
Hardware XOR engine by dedicated ASIC266 chipsets
Dual-speed fans to reduce noise
Enhanced modular enclosure design
DDR Memory up to 2GB
RAID
Multiple arrays configurable with
dedicated or global hot spares
Copying and replacing drives with
drives of larger capacity
Automatic background rebuilds
Configurable stripe size and write
policy per array
Intelligent drive handling:
In degraded mode: skips irreparable
blocks to continue rebuild
In normal operation: data-block
verification and repair
Subsystem Components
Single controller
configuration provides full RAID
functionalities
One (1) EonStor enhanced 3U
enclosure
One (1) RAID controller module
One (1) 512MB DDR RAM DIMM module
(pre-installed on the controller
modules)
Two (2) hot-swappable, redundant,
530W power supply units (PSUs)
Two (2) redundant, dual-fan cooling
modules running in high/low speeds
One (1) optional BBU
Sixteen (16) hot-swappable drive
trays
Two (2) front handles
Host Interface
Two (2) FC-4G host channels; backward
compatible with 1 or 2G-FC
Auto-negotiate FC-AL, point-to-point, or
switched fabric
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or
sequential I/Os
Drive Interface
Sixteen (16) hot-swappable 3Gbps SATA-II
(3Gbps) drive trays that accommodate 1-inch
pitch, 3.5-inch SATA-II (3Gbps) or SATA-I
disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected
drive
Management
Firmware-embedded utility via LCD keypad
or RS-232C port
Host-side SES emulation with
pass-through to back-end SES emulation
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
10/100 BaseT Ethernet for out-of-band
management
Two (2) COM ports for local access to
firmware-embedded utility and UPS
connectivity
Java-based SANWatch software with
Snapshot protection:
Graphical user interface
Local/remote management; in-band or
out-of-band via TCP/IP
Centralized management to monitor
and administer multiple RAID units on
one screen
Secure link over SSL
Configuration Client for easy access to
the configuration utility screen
SNMP 2.0 MIBs with get and set commands
SAN Management
Up to 1024 LUNs (if
sufficiently large memory is used with the
proper settings)
Indicators
Onboard alarm is triggered when one of
the following fails:
RAID controller module
Cooling module
Power supply unit
Hard drive
BBU module
Module status LED indicators:
Two (2) per drive tray
Three (3) per LCD panel
Six (6) per RAID controller module
One (1) per Fibre port
Two (2) per Ethernet port
Two (2) per cooling module
One (1) per power supply unit
One (1) per BBU module
Module failure alert through I2C
bus
Event notifications sent over email,
fax, LAN broadcast, SNMP traps, MSN
messenger, SMS short messages
System alerts through Java-based
SANWatch manager
IOSmart
IOSmart allows for the
flexible configuration of logical drives,
logical volumes and logical partitions and
ensures instant RAID availability via background
logical drive initialization. Fibre loops' load
balancing is provided within the subsystem. The
firmware's embedded intelligent algorithms, such
as Adaptive Write Policy and Guaranteed Latency
I/O, improve sequential write performance and
ensure the fast and continuous flow of data.
DrvSmart
The DrvSmart utility provides
an easy way to store data while keeping it safe.
One of the main DrvSmart functions, Media Scan,
retrieves data from degraded or damaged hard
drives and handles low quality drives in both
the degraded mode and during the rebuild
process. Other DrvSmart features include disk
cloning, drive roaming, SMART, transparent
resetting of non-responsive hard drives, and
RAID parity update tracking and recovery.
SysSmart
SysSmart combines enclosure
monitoring and firmware management capabilities
in order to minimize the chance of down time
caused by hardware failures. The Auto data
protection mechanisms are developed to ensure
data safety. Other SysSmart functions include
the event-triggered and the various monitoring
utilities and monitoring approaches combined
with the powerful RAIDWatch manager. Component
status, voltage and temperature readings, and
system events are instantly revealed through the
manager's graphical interface.
Physical/Electrical
Interfaces
Two (2) FC ports, each using a
short-wavelength adapter
Two (2) COM ports on the controller
module for RS-232C serial port (38400, n, 8,
1) and UPS support
One (1) 10/100BaseT Ethernet port on the
controller module
Power Supply Module
Two (2) redundant, hot-swappable power supplies
with PFC
Input
100VAC~240 VAC with 530W PFC
(auto-switching)
47 to
63Hz
Output
(Maximum
output: 460 Watts)
+12.0V
32A max.
+ 5.0V
32A max.
+ 3.3V
30A max.
Dimensions
248.9(D)
x 128(W) x 82.1(H) mm (9.8 x 5 x 3.2
inches)
Cooling Module
Two (2) redundant, dual-fan cooling modules
Maximum
Air Flow
High
speed: 31.8 DFM
Low speed: 20.1 CFM
Environmental Specifications
Temperature
Operating: 0º to
40ºC (32º F to 104º F) (without BBU)
Operating: 0° to 35°C (32° F to 95 °
F) (with BBU)
Non-operating: - 40º to 60ºC (-40º F
to 140º F)
Relative
humidity
Operating: 10%
to 80% (non condensing)
Non-operating: 10 to 95% (non
condensing)
Altitude
Operating: sea
level to 12,000 ft
Non-operating: sea level to 40,000
ft
Dimensions
Chassis without handles: 445(W) x 130(H)
x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
Chassis with handles: 482.6(W) x 131(H)
x 504.3(D) mm (19 x 5.2 x 19.9 inches)
Package: 423(H) x 567(W) x 772(D) mm
(16.7 x 22.3 x 30.4 inches)
System weight (w/o drives)
Net weight: 28.5kg (62.7 pounds)
Gross weight: 30.5kg (67.1)
There are no accessories for this