Rackmount Server - Rackme Series
SAN
>>
3U
>> NSS3U16SAR-FC
NSS3U16SAR-FC
The NSS3U16SAR-FC SAN-ready subsystem combines the cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth.Redundant Controller Installed.
ï
The NSS3U16SAR-FC SAN-ready subsystem combines the cost-effective
SATA drives in a high availability 4G FC array. IT managers will
find it is an easy-to-use and easy to maintain storage solution for
their DAS, Fibre Channel SAN and clustered servers or any
application requiring dedicated bandwidth.
FC-4G to SATA-II (3Gbps) RAID subsystem
Eight (8) FC-4G host ports w/ onboard bypass
Redundant, active-active RAID controllers
Hardware RAID6 XOR by dedicated ASIC400 chipsets
Intelligent load-balancing; internally & between host links
by the EonPathâ„¢ multi-path software
Proactive parity and media error manual and scheduled
scan/repair
High-availability, modular enclosure design
Adaptive writer policy
Up to 2GB cache per controller
RAID Controller
Hardware RAID parity computing
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30,
50, 60, and NRAID
RAID Migration
Configurable stripe size and write policy
per array
Multiple Global, Dedicated, &
Enclosure-specific hot-spares
Intelligent Drive Handling:
In degraded mode: skips irreparable
blocks to continue rebuild
In normal operation: data-block
verification and repair
Host Interface
Eight (8) FC-4G host port w/HUB functions
Concurrent I/O commands
Tagged command queuing up to 256
Adaptive cache write policies
Drive Interface
Sixteen (16) 3.0Gbps SATA-II (3Gbps) ,
hot-swappable drive trays
Accommodates 1-inch pitch, 3.5-inch SATA-II
(3Gbps) disk drives
S.M.A.R.T. and NCQ support· Automatic
bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components
Heavy duty 3U enclosure
Dual-redundant RAID controller modules
One (1) 512MB DDR RAM DIMM module (default,
supports up to 2GB in size) on each controller
Two (2), hot-swappable, redundant, 530W
power supply units
Two (2), redundant, dual-speed cooling
modules
Sixteen (16), hot-swappable drive trays
Two (2) forearm handles
LCD keypad panel
Li-Ion, life expectancy & charge level aware
battery backup unit (BBU)
Management
COM1 serial port for local access to
firmware-embedded utility
COM2 for UPS connection
GUI, Telnet, and SSH system monitoring via
Ethernet
Java-based SANWatch software with Snapshot
protection
Firmware-embedded manager via RS-232C (audio
jack) that is platform independent
Widest range of event notification methods
including email, LAN broadcast, fax, SNMP traps,
SMS, and MSN
LCD keypad panel to all configuration
options
Variable logical drive options per DIMM size
Module status LED indicators:
Two (2) per drive tray
Seven (7) per controller module
One (1) per power supply unit
One (1) per BBU module
Two (2) per cooling module
Module failure alert through I 2
C bus
Interfaces
One (1) Fast Ethernet management port
Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module Two (2) redundant hot-swappable
power supplies with PFC
Input
100~240VAC with 530W PFC
(auto-switching)
47 to
63Hz
Output
(Maximum
output: 530 Watts)
+12.0V
30A max.
+ 5.0V
32A max.
+ 3.3V
32A max.
Cooling Module
Two (2) redundant dual-fan cooling modules
Maximum air
flow:
High speed:
90 CFM
Low speed: 70 CFM
Environmental Specifications
Operating
temperature:
0º to 40ºC (35ºC w/
battery)
Non-operating
temperature:
- 40º to 60ºC
Relative humidity:
5 to 95%,
non-condensing
Altitude:
Operating: sea level
to 12,000 ft
Non-operating: sea level to 40,000 ft
Dimensions:
Chassis without handles: 445(W) x 130(H) x
488.2(D) mm (17.5 x 5.1 x 19.2 inches)
Chassis with handles: 482.6(W) x 131(H) x
504.3(D) mm (19 x 5.2 x 19.9 inches)
Package: 423(H) x 567(W) x 772(D) mm (16.7 x
22.3 x 30.4 inches)
System weight:
Net weight: 28kg
Gross weight: 31kg (without drives)
There are no accessories for this product
at this time.