Combining the high performance, reliability, and extensive connectivity of 4G Fibre Channel interfaces with the cost-effective SATA drive technology, these entry-level, SAN-ready subsystems provide clustering capabilities for DAS, Fibre Channel SAN, and are well suited for imaging and archiving or secondary storage.
Combining the high performance, reliability,
and extensive connectivity of 4G Fibre Channel interfaces with the
cost-effective SATA drive technology, these entry-level, SAN-ready
subsystems provide clustering capabilities for DAS, Fibre Channel
SAN, and are well suited for imaging and archiving or secondary
storage.
FC-4G to SATA-II (3Gbps) single controller RAID subsystem
RAID5 configuration end-to-end I/O performance
Sequential read:545 MB/sec
Sequential write:345 MB/sec
Dual-speed fans to reduce noise
2U chassis providing up to 8TB or 12TB of storge capacity
SATA NCQ support
RAID
Multiple arrays configurable with dedicated or
global hot spares
Copying and replacing drives with drives of
larger capacity
Automatic background rebuildsConfigurable stripe
size and write policy per arrayIntelligent drive
handling:
In degraded mode: skips irreparable blocks to
continue rebuild
In normal operation: data-block verification and
repair
Host Interface
Two (2) FC-4G through two (2) SFP host ports
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface
Twelve (12) or eight (8) 3Gbps SATA-II (3Gbps) ,
hot-swappable drive trays that accommodate 1-inch pitch,
3.5-inch SATA-I or SATA-II (3Gbps) disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components
Single controller configuration provides full RAID
functionalities
One (1) EonStor enhanced 2U enclosure
One (1) RAID controller module
One (1) 256MB DDR RAM DIMM module (pre-installed
on the controller module)
Two (2), hot-swappable, redundant, 350W power
supply units
Three (A12F) or Two (A08F), hot-swappable,
redundant, single-fan cooling modules running in
high/low speeds
Twelve (12) or eight (8), hot-swappable drive
trays
Two (2) front handles
Optional battery backup unit
Management
Front LCD control panel for setup and configuration10/100
BaseT Ethernet for out-of-band managementOne (1) RS-232C
serial port for local access to firmware-embedded utility
Firmware-embedded Java-based RAIDWatch® GUI manager:
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
Cross-platform, remote administration with SSL
Out-of-band access via Ethernet
Centralized management to monitor and administer
multiple RAID units on one screen
Configuration client for real-time event notification
over Email, Fax, LAN broadcast, SNMP Traps, MSN
messenger,SMS short messages, and the configuration utility
screen
Indicators
Onboard alarm is triggered when one of the following
modules fails:
RAID controller module
Cooling module
Power supply unit
Hard drive
BBU module
Module status LED indicators:
Two (2) per drive tray
One (1) per cooling module
One (1) per power supply unit
One (1) per BBU module
Three (3) per LCD panel
Five (5) per RAID controller module
Two (2) per Ethernet port
Module failure alert through I2C bus
Intelligent Drive Handling
If two bad blocks occur on two member drives of an array,
the integrity of the stored data is endangered. Media Scan,
Infortrend's innovative intelligent drive handling function,
retrieves data from the damaged sectors. Media Scan handles
low quality drives in both the degraded mode and during the
rebuild process. For additional data security, other
intelligent drive management features include the
transparent resetting of hung hard drives, power-failure
management, and bad-drive handling during LD expansion.
Task Scheduler
The Task Scheduler is combined with Media Scan so that
the scanning operation can be scheduled beginning at a
specified start time and repeating at the configurable
intervals. The operation is thus hands free. Each such
schedule can be defined to operate on individual hard
drives, all drives of a certain class, all member drives of
a specified logical drive, or all member drives of all
logical drives.
Interfaces
Two (2) SFP ports for host connections
One (1) COM port (38400, n, 8, 1)
One (1) 10/100BaseT Ethernet port
Power Supply Module
Two (2) redundant hot-swappable power supplies with PFC
Input
100VAC at 6A, 240VAC
at 3A with PFC (auto-switching)
47 ~ 63Hz
Output
(Maximum output: 350
Watts)
+12.0V
25A max.
+ 5.0V
25A max.
+ 3.3V
20A max.
Cooling Module
Three (A12F) or two (A08F) redundant single-fan cooling
modules
Maximum air flow
(each module)
High speed: 31.8 CFM
Low speed: 20.1 CFM
Environmental Specifications
Operating temperature
0° to 40°C
Non-operating temperature
- 40º to 60ºC
Relative humidity
5 ~ 95%, non-condensing
Operating altitude
Operating: 0 ~ 12,000 ft
Non-operating: 0 to 40,000 ft
Dimensions
Chassis without handles: 446(W) x 88(H) x 490(D) mm
Chassis with handles: 482 (W) x 88(H) x 505(D) mm
Package: 381H x567W x 772D mm
System Weight
Net weight: 23.5kg
Gross weight: 25kg
There are no accessories for this product at this time.