Home   Contact Us    Site Map
QUOTE  |  SUPPORT  | CONTACT

HOME

SERVER

STORAGE

GPU COMPUTING

CLUSTERS

CUSTOMERS

PARTNERSPRESSCOMPANY
1-877-NEW-TECH  Twitter Facebook

Categories:

Storage Servers
Storage Systems
Rackmount Server
    1U Rackmounts
    2U Rackmounts
    3U Rackmounts
    4U Rackmounts
    5U Rackmounts
    6U Rackmounts
    7U Rackmounts
    8U Rackmounts
    9U Rackmounts
Blade Server
GPU Computing
HPC
Desktop/Workstation
Rugged Servers
Portable Computer
Rackmount LCDs / KVMs
NoteBooks & Mobile
Mini ITX
Mini Box

Rackmount Server - Rackme Series

SAN  >>   2U     >> NSS2U12SSR
 
NSS2U12SSR   NSS2U12SSR
High density RAID subsystem with 4 SAS wide host ports, the NSS2U12SSR provides a throughput performance around 800MBps. Integrators can build tiered storage to support high-reliability SAS drives for mission-critical operations and cost-effective SATA-II drives for near-line backup, distribution, or archival uses. Redundant Controller Installed.
 
ï
 

High density RAID subsystem with 4 SAS wide host ports, the NSS2U12SSR provides a throughput performance around 800MBps. Integrators can build  tiered storage to support high-reliability SAS drives for mission-critical operations and cost-effective SATA-II drives for near-line backup, distribution, or archival uses.

  • SAS to SAS/SATA-II RAID subsystem
  • Redundant RAID controller
  • EonPath multi-pathing, load-balancing software
  • 4 SAS 4x wide host ports
  • Hardware RAID6 engine by dedicated ASIC400 chipsets
  • Superior performance w/ uncomplicated connectivity
  • 12 SAS or SATA-II disk drives
  • Expansion to 48TB via 4x wide expansion port
  • Corresponding JBODs:
    S12S-J1002-R (dual-controller)

 

 

 

 

Specifications

RAID

  • Hardware RAID5 & RAID6
  • Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID
  • RAID Migration
  • Configurable stripe size and write policy per array
  • Multiple Global, Dedicated, & Enclosure-specific hot-spares
  • Intelligent Drive Handling:
    • In degraded mode: skips irreparable blocks to continue rebuild
    • In normal operation: data-block verification and repair

Host Interface

  • 4 SAS wide ports
  • 12Gbps bandwidth (half duplex) per port
  • Concurrent I/O commands
  • Tagged command queuing up to 1024
  • Max. command queue up to 1024
  • Fault-tolerant host links with the EonPath multi-pathing software
  • Included cables:
    • NSS2U12SSR – 2x Mini-SAS-to-Mini-SAS SFF-8088 120cm cables

Drive Interface

  • 12 3.0Gbps SAS/SATA-II, hot-swappable drive trays
  • Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
  • S.M.A.R.T. and NCQ support
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive
  • In-band enclosure service through the expansion links from expansion enclosures
  • Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
  • MUX kits with port selectors for dual-controller access to SATA drives

    System Components

  • High density, smartly managed 2U enclosure
  • Dual redundant RAID controller
  • One DIMM module with capacities from 512MB to 2GB
  • Redundant, hot-swappable 530W power supply units
  • Redundant, dual-speed cooling modules 
  • Twelve (12), hot-swappable drive trays
  • Two (2) forearm handles
  • Li-Ion battery backup unit (BBU), life expectancy and charge level aware

Management

  • COM1 serial port for local access to firmware-embedded utility
  • COM2 for UPS connection
  • Automated cache flush and caching mode operation per enclosure status
  • GUI, Telnet, and SSH system monitoring via Ethernet
  • Java-based SANWatch software with Snapshot protection
  • Firmware-embedded manager via RS-232C (audio jack) that is platform independent
  • Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  • LCD keypad panel for monitoring and access to all configuration options
  • Variable logical drive options per DIMM size
  • Module status LED indicators:
    • Two (2) per drive tray
    • Seven (7) per controller module
    • One (1) per power supply unit
    • One (1) per BBU module
    • Two (2) per cooling module
  • Presence detection & thermal sensors via I2C bus

Power Supply Module

Redundant hot-swappable power supplies with PFC

Input 100VAC at 10A, 240VAC at 5A with PFC (auto-switching)
47 to 63Hz
Output (Maximum output: 530 Watts)
+12.0V 43A max.
+ 5.0V 25A max.

Cooling Module

Redundant dual-thermal-fan cooling modules

Maximum Air Flow 90CFM (high speed); 70.7CFM (low speed)

Environmental Specifications

Operating temperature 5º to 40ºC  (35°C if battery is applied)
Non-operating temperature - 40º to 60ºC
Relative humidity 5 to 95%, non-condensing
Operating altitude Operating: 0 to 12,000 ft

Dimensions

  • Chassis without handles: 446(W) x 88(H) x 498(D) mm (17.56W x 3.46H x 19.6D inches)
  • Chassis with handles: 482 (W) x 88(H) x 516(D) mm (18.97W x 3.46H x 20.31D inches)
  • Package: 575W x 390H x 780D mm (22.63W x 15.35H x 30.7D inches)

Weight

  • NSS2U12SSR: Net weight - 18.71kg (41.16 pounds)
  • Gross weight – 25.9kg (56.98 pounds)



There are no accessories for this product at this time.





Solutions Rackmount Servers Storage Workstation
Rackmount Servers
Storage Servers
Blade Servers
HPC Cluster
Gpu Computing
1U Rackmount server
2U Rackmount server
3U Rackmount server
4U Rackmount server
5U Rackmount server
6U Rackmount server
7U Rackmount server
8U Rackmount server
9U Rackmount server
NAS
SAN
DAS
iSCSI
BackUp
Promise Technologies
Intel Workstations
AMD Workstations
GPU Supercomputing Workstations
High Performance Workstations
AMD FireStream
NVIDIA Tesla