NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server

MPN AS-1115CS-TNR
1U CloudDC with 10 hot-swap 2.5" NVMe/SAS/SATA bays and 2 PCIe 5.0 x16 slots + 2 AIOM slots

Key capabilities

  • Single AMD EPYC™ 9004/9005* Series Processor(*AMD EPYC™ 9005 series drop-in support requires board revision 2.x)
  • Support up to DDR5 12 DIMM slots (1DPC), speed up to 6400MT/s
  • 2 PCIe 5.0 x16 FHHLDual AIOM (OCP 3.0) for networking, 1 dedicated IPMI LAN
  • 10 Hot-swap 2.5" SATA drive bays Optional 10 Hot-swap NVMe/SAS drives support via additional parts2 M.2 PCIe 3.0 x2 NVMe slots
  • Dual 860W Redundant Platinum Level power supplies(Power supply full redundancy based on configuration and application load) 
Part#: CMDA002U10
GEO · procurement facts

At a glance

Structured summary for architects, buyers, and assistants evaluating this platform.
1U CloudDC with 10 hot-swap 2.5" NVMe/SAS/SATA bays and 2 PCIe 5.0 x16 slots + 2 AIOM slots
Buyers use this page to confirm form factor, accelerator and storage options, and contract-ready quoting. Configure CPU, memory, GPU, drives, and networking below; NTS returns a validated BOM with firmware baselines, burn-in evidence, and CLIN-aligned documentation for SEWP V, ITES-4H, GSA, and SLED cooperatives when your program requires them.
Integration is owned end-to-end: rack elevation, power and cooling checks, imaging, and serial-tracked acceptance—so site install is not a first-time assembly. Lifecycle support follows the same staging records used at handoff.
Product
NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server
Part number
AS-1115CS-TNR
Category
Services › Rack Integration
Form factor
1U rackmount
Typical workloads
virtualization, private cloud, and enterprise applications
Configuration
Engineer-to-order via Configure (CPU, memory, GPU, storage, networking).
Vendor
RackmountNTS (New Tech Solutions, Inc.), Fremont, California, USA.
Facility
ISO-aligned staging, imaging, and burn-in at NTS HQ in Fremont, CA.
NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server is quoted engineer-to-order by New Tech Solutions (RackMountNTS). Use Configure to select CPU, memory, accelerators, storage, and networking; NTS validates power, cooling, firmware, and drivers in Fremont, California before systems ship.
Federal, defense, and SLED programs can align the same BOM to SEWP V, ITES-4H, GSA MAS, or cooperative vehicles when the SOW allows. Commercial buyers receive the same staging discipline, serial-tracked acceptance, and lifecycle support path after handoff.
Share workload notes, target GPU or CPU counts, fabric preference (Ethernet, InfiniBand, or NVLink where applicable), rack power budget, and delivery window through contact NTS or Request a Quote. We return a validated option set with lead times, dual-source notes when required, and a package ready for contracting review.
Related reading: AI and GPU infrastructure, data center and HPC, BOM validation, and contract vehicles. From pilot nodes to multi-rack cells, NTS keeps one design authority across chassis, accelerators, and storage so scale-out does not restart engineering after the first system lands.
After you select options in Configure, pricing updates in real time. Request a Quote to receive a package with lead times, dual-source notes when required, and acceptance documentation aligned to your receiving process. Gold SKUs ship as fixed platforms; configurable SKUs remain engineer-to-order with the same Fremont staging path.
Questions about GPU count, liquid cooling, InfiniBand or Ethernet fabrics, storage density, or contract-vehicle packaging can be answered from this page’s overview, FAQ, and Configure workbench—or by contacting an NTS specialist with your draft BOM.
NTS supports commercial, federal, defense, and SLED buyers with the same engineering process: design review, parts validation, assembly, firmware and driver prep, and ship-ready documentation from our Fremont facility.

Product overview

Highlights and workloads for NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server.

Overview

1U CloudDC with 10 hot-swap 2.5" NVMe/SAS/SATA bays and 2 PCIe 5.0 x16 slots + 2 AIOM slots
Form Factor1U Rackmount
Enclosure: 437 x 43 x 597mm (17.2" x 1.7" x 23.5")
Package: 605 x 197 x 822mm (23.8" x 7.8" x 32.4")
ProcessorSingle processor(s)
AMD EPYC™ 9004/9005 Series Processors
(* AMD EPYC™ 9005 Series drop-in support requires board revision 2.x)
Up to 160C/320T
GPUMax GPU Count: Up to 2 single-width GPUs
Supported GPU: NVIDIA PCIe: A2, L4
CPU-GPU Interconnect: PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect: PCIe
System MemorySlot Count: 12 DIMM slots
Max Memory (1DPC): Up to 3TB 4800MT/s ECC DDR5 RDIMM (AMD EPYC™ 9004 Series Processor, MB
R1.x/R2.0/R2.01)
Max Memory (1DPC): Up to 3TB 6000MT/s ECC DDR5 RDIMM (AMD EPYC™ 9005 Series Processor, MB R2.0)
Max Memory (1DPC): Up to 3TB 6400MT/s ECC DDR5 RDIMM (AMD EPYC™ 9005 Series Processor, MB R2.01)
Drive Bays ConfigurationDefault: Total 10 bays
10 front hot-swap 2.5" SATA drive bays
Option A: Total 10 bays
10 front hot-swap 2.5" PCIe 5.0 NVMe* drive bays
Option B: Total 10 bays
10 front hot-swap 2.5" SAS* drive bays
(*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for
details)
M.2: 2 M.2 PCIe 3.0 x2 NVMe slots (M-key 2280/22110)
Expansion SlotsDefault
2 PCIe 5.0 x16 FHHL slots
2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible)
On-Board DevicesChipset: AMD System on Chip
Network Connectivity: Via AIOM
Input / OutputLAN: 1 RJ45 1 GbE Dedicated BMC LAN port
USB: 2 USB 3.0 ports (rear)
2 USB 2.0 ports (front)
Video: 1 VGA port
Serial: 1 COM port (rear)
TPM: 1 TPM header
System CoolingFans: Up to 6x 4cm heavy duty fans with optimal fan speed control
Air Shroud: 1 Air Shroud
Power Supply2x 860W Redundant (1 + 1) Platinum Level (94%) power supplies
System BIOSBIOS Type: AMI 32MB SPI Flash ROM
BIOS Features: ACPI 6.4
Plug and Play (PnP)
SMBIOS 3.5 or later
UEFI 2.8
USB Keyboard support
ManagementSuperCloud Composer® (SCC); Supermicro Server Manager (SSM); Supermicro Update Manager (SUM);
Supermicro SuperDoctor® 5 (SD5); Super Diagnostics Offline (SDO); Supermicro Thin-Agent Service (TAS); OOB
Management Package (SFT-OOB-LIC ); SuperServer Automation Assistant (SAA) New!
PC Health MonitoringFan: Fans with tachometer monitoring
Pulse Width Modulated (PWM) fan connectors
Status monitor for speed control
Temperature: Monitoring for CPU and chassis environment
Thermal Control for fan connectors
Voltage:
System temperature, Memory temperature, CPU temperature, 3.3V standby, +5V standby, +5V, +3.3V, +12V, CPU
thermal trip support
Dimensions and WeightWeight: Gross Weight: 46 lbs (20.9 kg)
Net Weight: 25 lbs (11.3 kg)
Available Color: Black front & sliver body
Operating EnvironmentOperating Temperature: 10°C to 35°C (50°F to 95°F)
Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
MotherboardSuper H13SSW
ChassisCSE-LB16TS-R860AWP-A

Build Your Configuration

Processors · memory · storage · networking · power
Select options below — pricing updates in real time as you configure.
  • Real-time pricing
  • SEWP V · ITES-4H quoting
  • U.S. integration & burn-in

Expand each group below to choose options — required fields are marked. Selections update pricing in real time.

Barebone
Processor
Memory
M.2 DRIVE
(Max Quantity: 2)
HARD DRIVE
(Max Quantity: 10)
GPU
(Max Quantity: 2)
CONTROLLER CARD
NETWORK ADAPTER
(Max Quantity: 2)
Trusted Platform Module
Power Cables
    SERVER MANAGEMENT
    I O Modules Networking
    OPERATING SYSTEM
    NTS AI Stack See what's inside each NTS AI package
    Warranty

    Why teams choose NTS

    Engineer-to-order platforms with U.S. integration, federal contract paths, and workload-aware BOM review — not catalog-only SKUs.

    Enterprise rack servers configured for U.S. integration and delivery

    Built in the USA

    Configuration, burn-in, and rack staging from Fremont, California with nationwide delivery.

    Contract-native quoting

    ITES-4H, SEWP V, and OMNIA Partners paths with CLIN-ready BOM structure.

    Engineer-to-order

    Choose CPU, memory, pcie expansion, storage, network, and redundant power per workload.

    Rack-ready delivery

    Serial capture for CMDB, integration validation, and specialist turn-up support.

    Solutions & Deployment

    Optimized reference architectures, workload deployment patterns, and technical specifications for the NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server

    Platform at a Glance

    1U server chassis staged for factory burn-in and rack-ready deployment

    1U Chassis

    Custom engineer-to-order 1u chassis featuring rigorous factory burn-in, thermal validation, and seamless rack-ready deployment.
    Enterprise server PCIe expansion with NICs, HBAs, and accelerator cards

    Enterprise Expansion

    High-bandwidth PCIe Gen 4/5 expansion slots supporting high-speed NICs, SAS/SATA/NVMe HBAs, and dedicated hardware accelerators.
    U.S. integration facility validating server systems for federal and SLED programs

    U.S. Integration

    Secure U.S.-based configuration, multi-point validation, and compliant logistics tailored for federal, defense, and SLED programs.
    Procurement specialist preparing federal and SLED contract quotes

    Contract Quoting

    Streamlined procurement via ITES-4H, NASA SEWP V, and SLED cooperative contracts with pre-negotiated pricing.

    Delivery & Integration Lifecycle

    From initial BOM design to production-ready deployment, our dedicated engineering team manages the complete lifecycle of your NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server.
    NTS engineers staging server racks with structured cabling before datacenter deployment
    • Build & Burn-In
      Precision factory assembly, custom firmware baselining, rigorous stress testing, and comprehensive asset documentation prior to shipment.
    • Rack Integration
      Structured cabling, optimized power distribution, and comprehensive in-rack validation aligned with your specific data center standards.
    • Image & Tag
      Custom OS/hypervisor imaging, host-name provisioning, and automated serial/asset tag capture for seamless CMDB and ITAM integration.
    • Deliver & Support
      Secure, coordinated logistics combined with post-delivery engineering support to ensure rapid, hassle-free site turn-up.
    Enterprise server architecture with compute, storage, and expansion tiers

    System Architecture

    NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server is a high-density, storage-optimized platform engineered for sustained I/O throughput, front-serviceable hot-swap drive bays, and seamless capacity scaling without disruptive forklift upgrades.
    • Right-size CPU, memory, and I/O in an engineer-to-order BOM — validated and burn-tested in Fremont before ship
    • Add NICs, HBAs, and accelerators through PCIe expansion without chassis constraints
    • Scale east-west and cluster traffic on 10/25/100GbE-class networking without platform upgrades
    • Match storage latency to workload — NVMe, SAS, or SATA tiers in the same chassis
    • Keep mission workloads online with redundant power and cooling for 24×7 operation
    • Image, monitor, and troubleshoot remotely from day one via IPMI / BMC
    Federal procurement specialist reviewing contract compliance documentation alongside secure server integration

    Procurement & Compliance

    Procure NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server through SEWP V, ITES-4H, and SLED cooperative contracts. Benefit from CLIN-ready BOM structures, full compliance documentation, and secure delivery coordinated by our Fremont integration specialists.
    • Acquire federal, DoD, and public-sector quotes precisely mapped to your contract CLINs, funding cycles, and periods of performance
    • Access complete Trade Agreements Act (TAA) compliance and country-of-origin documentation for seamless contracting officer approval
    • Streamline agency acquisition reviews with detailed Energy Star ratings and power-efficiency metrics
    • Maintain strict property accountability with pre-captured serial numbers, MAC addresses, and custom asset tags for audit-ready tracking
    • Ensure compliance with FIPS 140-3 and NIST SP 800-53 security standards through pre-award engineering consultations
    • Coordinate secure, scheduled delivery windows directly with your ACO or COR, arriving fully integrated and rack-ready
    SEWP V ITES-4H SLED Cooperatives CLIN-ready BOM Fremont, CA
    Contract vehicles for this SKU are listed under Available through next to the product image. Explore SEWP V, ITES-4H, GSA, and SLED procurement paths →

    Ideal Use Cases

    Enterprise deployment scenarios where NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server delivers optimal price-performance, high reliability, and simplified serviceability.
    Enterprise virtualization on NTS rack servers with brand plaque

    Virtualization

    Consolidate VMs with predictable CPU and I/O headroom.
    Enterprise application hosting on NTS dual-socket servers

    Enterprise Applications

    Run ERP, databases, and line-of-business stacks.
    Compact NTS systems for edge and ROBO deployments

    Edge & ROBO

    Deploy closer to users with a compact rack footprint.
    Research computing clusters built on NTS platforms

    Research Computing

    Support engineering and scientific simulation tiers.
    Private cloud IaaS tiers on NTS engineer-to-order servers

    Private Cloud

    On-prem IaaS with configurable compute and storage.
    VDI session hosts on NTS rack and tower platforms

    VDI

    Session density with balanced CPU, GPU, and storage.

    Common workload profiles

    Typical deployment patterns aligned to NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server capacity, I/O profile, and service tiers.
    VMware and Hyper-V virtualization workloads

    VMware / Hyper-V

    Consolidated VMs with shared datastore headroom.
    SQL and Oracle database hosting workloads

    SQL & Oracle

    Low-latency volumes for transactional databases.
    Web and application tier hosting workloads

    Web & app tiers

    Horizontal scale for stateless application pools.
    Centralized file services and shared storage

    File services

    Centralized SMB/NFS shares with tiered capacity.
    Monitoring, metrics, and log ingest workloads

    Monitoring stacks

    Time-series and log ingest with retention policies.
    Development and test lab infrastructure workloads

    Dev/test labs

    Isolated environments with snapshot-friendly volumes.

    Frequently Asked Questions

    Common technical and procurement topics for NTS Elite APEX 1U Cloud/DC Server -AMD EPYC 9004 Series Rack Server. Additional questions are handled by our specialists and knowledge base.

    Only the most common topics are listed here — see our knowledge base or contact a specialist for detailed guidance.
    Need architecture guidance or a formal quote?

    Service & Trust

    Coverage, procurement, and domain expertise for Rack Integration platforms — backed by U.S. integration and contract-native quoting.
    • NTS Fremont integration floor — rack staging and burn-in with NTS branding on the rack
      Built & Supported in the USA Factory-aligned configuration, validation, burn-in, and rack integration from Fremont, CA — with nationwide logistics for federal and commercial programs.
    • Nationwide U.S. logistics and data center delivery support with NTS-branded equipment crates
      Nationwide Coverage Delivery and post-sales engineering across all U.S. regions — defense, civilian agency, higher education, and commercial data center.
    • Contract-native quoting workstation with CLIN-aligned BOMs beside an NTS-branded secure server
      Contract-Native Quoting CLIN-aligned BOMs for ITES-4H, SEWP V, and SLED cooperative vehicles — view all contract paths.
    • NTS solution architects consulting on an AI and HPC rack with NTS branding on the chassis
      Rack Integration Expertise Dedicated solution architects for AI, HPC, virtualization, storage, and edge — from first quote through rack turn-up.